![Samsung S3C2501X Скачать руководство пользователя страница 334](http://html.mh-extra.com/html/samsung/s3c2501x/s3c2501x_user-manual_340828334.webp)
S3C2501X
ETHERNET CONTROLLER
7-45
7.5.2 THE MII STATION MANAGER
The MDIO (management data input/output) signal line is the transmission and reception path for control/status
information for the station management entity, STA. The STA controls and reads the current operating status of
the PHY layer. The speed of transmit and receive operations is determined by the management data clock,
MDC.
The frame structure of the STA that writes command to control registers, or which reads the status register of a
PHY device, is shown Table 7-30. The PHY address is defined as the identification (ID) value of the various PHY
devices that may be connected to a single MAC. Register addresses can contain the ID value for up to 32 types
of PHY registers.
Turn-around bits are used to regulate the turn-around time of the transmit/receive direction between the STA and
a PHY device. So that the STA can read the set value of a PHY device register, it must transmit the frame data,
up to a specific register address, to the PHY device. During the write time (which is an undirected transmission),
the STA transmits a stream of turn-around bits. As a result, by transmitting a write or read message to a PHY
device through the MDIO, the STA can issue a request to set the operation or to read the operation status.
As its response this message, the PHY device resets itself, sets loop-back mode, selects active/non-active auto-
negotiation process, separates the PHY and MII electrically, and determines whether or not to activate the
collision detection process.
When it receives a read command, the PHY reports the type of PHY device such as 100 base-T4, FDX 100
base-X, HDX 100Base-X, 10M-b/s FDX, or 10M-b/s HDX.
Table 7-30. STA Frame Structure Description
Preamble
Start of
Frame
Operation
Code
PHY
Address
Register
Address
Turnaround
Data
Idle
Write
(Command)
11111111
(32 bits)
01
01 (write)
5 bits
5 bits
10 (2 bits)
16 bits
(register
value)
Z
Read (Status)
11111111
(32 bits)
01
10 (read)
5 bits
5 bits
Z0
16 bits
(register
value)
Z
Direction: STA to PHY
Direction: PHY to STA
Содержание S3C2501X
Страница 1: ...S3C2501X 32 BIT RISC MICROPROCESSOR USER S MANUAL Revision 1 查询S3C2501X供应商 捷多邦 专业PCB打样工厂 24小时加急出货 ...
Страница 18: ......
Страница 275: ...MEMORY CONTROLLER S3C2501X 5 60 NOTES ...
Страница 289: ...I2C CONTROLLER S3C2501X 6 14 NOTES ...
Страница 373: ...GDMA CONTROLLER S3C2501X 9 24 NOTES ...
Страница 435: ...I O PORTS S3C2501X 12 12 NOTES ...
Страница 463: ...ELECTRICAL DATA S3C2501X 15 6 NOTES ...