INSTRUCTION SET
S3C2501X
3-48
3.12.3 DATA ABORTS
If the address used for the swap is unacceptable to a memory management system, the memory manager can
flag the problem by driving ABORT HIGH. This can happen on either the read or the write cycle (or both), and in
either case, the data abort trap will be taken. It is up to the system software to resolve the cause of the problem,
then the instruction can be restarted and the original program continued.
3.12.4 INSTRUCTION CYCLE TIMES
Swap instructions take 1S + 2N +1I incremental cycles to execute, where S, N and I are defined as squential (S-
cycle), non-sequential, and internal (I-cycle), respectively.
3.12.5 ASSEMBLER SYNTAX
<SWP>{cond}{B} Rd,Rm,[Rn]
{cond}
Two-character condition mnemonic. See Table 3-2.
{B}
If B is present then byte transfer, otherwise word transfer
Rd,Rm,Rn
Expressions evaluating to valid register numbers
Examples
SWP
R0,R1,[R2]
; Load R0 with the word addressed by R2, and
; store R1 at R2.
SWPB
R2,R3,[R4]
; Load R2 with the byte addressed by R4, and
; store bits 0 to 7 of R3 at R4.
SWPEQ
R0,R0,[R1]
; Conditionally swap the contents of the
; word addressed by R1 with R0.
Содержание S3C2501X
Страница 1: ...S3C2501X 32 BIT RISC MICROPROCESSOR USER S MANUAL Revision 1 查询S3C2501X供应商 捷多邦 专业PCB打样工厂 24小时加急出货 ...
Страница 18: ......
Страница 275: ...MEMORY CONTROLLER S3C2501X 5 60 NOTES ...
Страница 289: ...I2C CONTROLLER S3C2501X 6 14 NOTES ...
Страница 373: ...GDMA CONTROLLER S3C2501X 9 24 NOTES ...
Страница 435: ...I O PORTS S3C2501X 12 12 NOTES ...
Страница 463: ...ELECTRICAL DATA S3C2501X 15 6 NOTES ...