5.7.8 BASIC OPERATION
SDRAM initialization sequence
On power-on reset, software must initialize the SDRAM controller and each of the SDRAM connected to the
controller. Refer to the SDRAM data sheet for more detailed information on the start up procedure for the
SDRAM used. Typical example sequence is given below :
1.
Wait 200us to allow SDRAM power and clocks to stabilize.
2.
Program the INIT[1:0] of the CFGREG to
01
. This automatically issues a
PALL
command to the SDRAM.
3.
Write 0xF into the refresh timer register. This provides a refresh cycle every 15 clock cycles.
4.
Wait for a time period equivalent to 120 clock cycles (8 refresh cycles).
5.
Program the normal operational value into the refresh timer.
6. Program the CFGREG to their normal operation values.
7. Program the INIT[1:0] to
10
. This automatically issues a
MRS
command to the SDRAM.
8.
Program the INIT[1:0] to
00
. The controller enters the normal mode.
9.
Program the CMDREG and WBTOREG to their normal operation values.
10. The SDRAM is now ready for normal operation.
Содержание S3C2501X
Страница 1: ...S3C2501X 32 BIT RISC MICROPROCESSOR USER S MANUAL Revision 1 查询S3C2501X供应商 捷多邦 专业PCB打样工厂 24小时加急出货 ...
Страница 18: ......
Страница 275: ...MEMORY CONTROLLER S3C2501X 5 60 NOTES ...
Страница 289: ...I2C CONTROLLER S3C2501X 6 14 NOTES ...
Страница 373: ...GDMA CONTROLLER S3C2501X 9 24 NOTES ...
Страница 435: ...I O PORTS S3C2501X 12 12 NOTES ...
Страница 463: ...ELECTRICAL DATA S3C2501X 15 6 NOTES ...