STRG(?){i}
The STRG? command sets or queries the trigger way of data sampling. The parameter i
selects inner trigger mode <INT> (i=0) or outer trigger mode <EXT> (i=1).
SPRM(?){i}
The SPRM? command sets or queries the mode of data sampling. The parameter i selects
<Single> mode (i=0) or <Loop> mode (i=1).
STRD
The STRD command starts or continues data sampling.
PAUS
The PAUS command pauses data sampling.
REST
The REST command resets the data buffers. This command will empty the four data
buffers, including Buffer1 to Buffer4.
4.2.9 Data Read Commands
OUTP? i
The OUTP? i command is used to read a single parameter value. The parameter i selects the
parameters as the following.