T6891
062AZ005A
2
FEATURES
2-24
2.3.6.2
CHS200 sound pressure level
(EN ISO 11202)
Test conditions
- Operating conditions: work cycle with no load.
- Type of processing: cap inspection.
- Operating cycle: cap inspection (1500 insp/min).
- Test environment: industrial factory with reflective floors.
Test conditions with load (CHS plus directing unit and caps)
- Operating conditions: complete work cycle.
- Type of processing: cap inspection.
- Operating cycle: cap feed and inspection (1500 insp/min).
- Test environment: industrial factory with reflective floors.
Instruments used
Class 1 instruments (IEC 804)
P1
- Control post, measured at a height of 1.55 m from the floor.
L
pA
- Acoustic pressure emitted, weighed
A
and corrected over time.
L
pC peak
- Peak
C
-weighted instantaneous sound pressure level.
FIGURE 2.3.6.2 - CHS200 SOUND PRESSURE LEVEL
Measured values
L
pA
dB(A)
L
pC peak
dB(C)
P1
74.2
91.5
Values measured with load
L
pA
dB(A)
L
pC peak
dB(C)
P1
79.8
94.3