062AZ005A
6
OPERATING INSTRUCTIONS
6-4
6.2
WORK CYCLES
(References in figure CHS OPERATOR INTERFACE in this chapter)
6.2.1
WORK CYCLE IN MANUAL MODE
Operations in MANUAL mode must only be performed during the adjustment and/or diagnostics phases to analyze
individual operations.
The operators must pay special attention when performing these operations.
The mode selector
8
must be turned to MANUAL.
Perform manual operations with the start and stop button of the conveyor belt
6
, start and stop button of the spacer
5
and start and stop button of the suction device
7
. Perform manual operations on pneumatic actuators with the
controls provided on the dedicated page in the operator interface.
Adjust speed in manual mode with the operator interface.
6.2.2
LOCAL MODE (AUTOMATIC)
6.2.2.1
Normal cycle
Normal start-up refers to a start-up that does not require adjustments for image shooting and/or loading of
configurations that are different from the existing ones the last time the system was shut off. This is case in which the
machine re-starts and continues to inspect the product it was calibrated for at the last shut off.
The following procedure is used for each image to sample:
- Activate the main switch on the main electrical cabinet
9
: look at the screen to make sure the PC start-up operations
are correct and that no warning or error messages appear.
- Press the reset button
2
to start the machine.
- Press the automatic cycle start button
3
to start the inspection cycle.
6.2.2.2
Product configuration change
This type of start-up implies that the software configuration from the last shut off must be changed and the adjustments
made to image shooting must be maintained for the sensors, ejection and conveyor stations. This is the case in which
a production change is made while maintaining the mechanical format of the pieces to be inspected with a variation
of color shade, for example.
The following procedure is used for each image to sample:
- Activate the main switch on the main electrical cabinet
9
: look at the screen to make sure the PC start-up operations
are correct and that no warning or error messages appear.
- Press the reset button
2
to start the machine.
- Load the appropriate product.
- Start the system in inspection mode.
- Place good quality pieces on the conveyor belt. The vision system must accept the good quality pieces that arrive.
- Place defective pieces on the conveyor belt. The pieces should present all the various defects the machine has
been set to eject. The vision system must reject all the defective pieces that arrive.
- If good quality pieces are rejected or defective pieces are not ejected, identify and eliminate the cause of the fault
before proceeding.
- Save the product.
Содержание Imola CHS Series
Страница 2: ......
Страница 4: ...062AZ005A...
Страница 8: ...062AZ005A TABLE OF CONTENTS Page 0 8 9 DISMANTLING 9 1 9 1 DECOMMISSIONING 9 1 9 2 DISMANTLING 9 2...
Страница 15: ...062AZ005A GENERAL INFORMATION 1 1 7 FIGURE 1 8 B CHS200 MACHINE IDENTIFICATION PLATE T6864 E0206...
Страница 48: ...062AZ005A 2 FEATURES 2 32...
Страница 74: ...062AZ005A 4 INSTALLATION 4 8 FIGURE 4 3 2 1 B CONNECTING THE SPARK TESTER DEVICE ELECTRIC CABLES...
Страница 76: ...062AZ005A 4 INSTALLATION 4 10...