062AZ005A
ADJUSTMENTS
7
7-17
SENSOR
REFERENCE OBJECT
DISTANCE X
(mm)
SQ6
Turn-plate/piston timing sensor
0.5-1
(see paragraph ADJUSTING CYLINDER
YV3 AND TIMING SENSOR SQ6 IN THE
TURN-PLATE SPACER)
PHOTOCELLS WITH
REFLECTOR
REFERENCE OBJECT
DISTANCE X
(mm)
SQ2
Minimum level
cap feed channel
-
SQ7
Maximum level
cap feed channel
-
SQ53/SQ101
Check caps entering belt 1
-
SQ102
Check signal, Belt 1 reject
-
SQ11
Check caps leaving belt 1
-
SQ53B/SQ103
Check caps entering belt 2
-
SQ104
Check signal, Belt 2 reject
-
SQ11B
Check caps leaving belt 2
-
-
ELECTRIC LOCK
LIMIT SWITCH
REFERENCE OBJECT
DISTANCE X
(mm)
SQ42
Guard safety
Spark tester/turn-plate
-