T6904
062AZ005A
7
ADJUSTMENTS
7-18
7.3.11
ADJUSTING THE IMAGE CAPTURE
- Adjust light support
1
positioning. The height among the lights and the cap slide plate must be the same as the
height of the cap to be inspected plus 5 mm.
- Adjust camera support
2
positioning. Make sure the diameter of the cap to be inspected framed by the camera is
equal to 80%±1% of the shortest side of the acquisition frame. At the same time, make sure the image is focused
with the contrast device.
- Adjust focusing and brightness using the focus lens
3
in order to obtain clear images for the vision system.
FIGURE 7.3.11 - ADJUSTING THE IMAGE CAPTURE
1
Light support
2
Camera support
3
Focus lens
2
3
1