Operator, Basic Setting and Commissioning
4-17
CSD7 Servo Drive (EtherCAT)
Startup 2 : Start Up the Drive by Changing the Speed
Start up the drive by changing the speed from the initial value, 50
[rpm] to 1000 [rpm].
The change of Jog operation speed should be done at 0x2205 (Ft-
2.05). The speed set here is not related to other operation, and
applied only upon the Jog operation. Setting range is 0 to 6000
[rpm]. Initial value is 50 [rpm].
Change the Jog operation speed by according to the following
flowchart.
ㅌ
If setting is wrong, the setting window does not blink when saving it
by pressing the MODE/SET key. If setting is completed normally,
retry the Jog operation [run-00]. You can see that the speed is
changed from 50 [rpm] to 1000 [rpm].
Status Display Mode
Flow Chart for Changing the Jog Speed
Power ON
Select the parameter setting
mode. with MODE/SET key,
Press Enter key for 2 secs to
enter the setting window.
make Ft-2.05 using
direction keys.
Make 1000 [rpm] using
direction keys.
Press MODE/SET key
to save it. (Blinking!)
Press Enter key for 2 secs to
exit the setting window.
Complete
Содержание OEMax CSD7
Страница 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Страница 4: ......
Страница 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Страница 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Страница 24: ......
Страница 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Страница 38: ......
Страница 76: ......
Страница 94: ......
Страница 114: ......
Страница 126: ......
Страница 314: ......
Страница 320: ...A 6 Specification and Exterior Dimensions CSD7 Servo Drive EtherCAT FigureA 5 400W FigureA 6 800W 1 5KW ...
Страница 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Страница 330: ......
Страница 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Страница 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...