Object Dictionary
7-13
CSD7 Servo Drive (EtherCAT)
Sub-Index 1
Restore All Default Parameters
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
4 byte(UDINT)
-
RW
No
-
-
-
Sub-Index 2
Restore Communication Default Parameters
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
4 byte(UDINT)
-
RW
No
-
-
-
Sub-Index 3
Restore CiA402 Deafult Parameters
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
4 byte(UDINT)
-
RW
No
-
-
-
Sub-Index 4
Restore CSD7 Specific Parameters
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
4 byte(UDINT)
-
RW
No
-
-
-
The object enables you to initialize parameters that is stored in the flash memory as the
factory-settings. To initialize parameters, write ‘load’ in each sub-index.
* ASCII code of ‘load’ ; ‘l’(0x6C), ‘o’(0x6F), ‘a’(0x61), ‘d’(0x64)
Hexadecimal value ; 0x64616F6C
▶
If ‘load’ is written to Sub-index 1, the parameters in the whole area of Table 45 will be
initialized. (Reserved)
▶
If 'load' is written to Sub-index 2, the parameters in the CoE Communication area of
Table 45 will be initialized. (Reserved)
▶
If 'load' is written to Sub-index 3, the parameters in the Device Profile area of Table 45
will be initialized. (Reserved)
▶
If 'load' is written to Sub-index 4, the parameters in the Manufacturer-specific area 1 - 4
of Table 45 will be initialized.
▶
The maximum number of times that you can write to the flash memory is 100,000.
▶
To save the initialization value to the flash memory, send 'save' to 0x1010.
0x1018
Identify Object
ALL
Sub-Index 0
Number of Entries
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
2 byte(UINT)
-
RO
No
-
-
-
Sub-Index 1
Vendor ID
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
4 byte(UDINT)
-
RO
No
-
-
-
Sub-Index 2
Product Code
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
-
4 byte(UDINT)
-
RO
No
-
-
-
Sub-Index 3
Revision Number
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
Содержание OEMax CSD7
Страница 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Страница 4: ......
Страница 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Страница 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Страница 24: ......
Страница 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Страница 38: ......
Страница 76: ......
Страница 94: ......
Страница 114: ......
Страница 126: ......
Страница 314: ......
Страница 320: ...A 6 Specification and Exterior Dimensions CSD7 Servo Drive EtherCAT FigureA 5 400W FigureA 6 800W 1 5KW ...
Страница 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Страница 330: ......
Страница 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Страница 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...