7-50
Object Dictionary
CSD7 Servo Drive (EtherCAT)
•
Position error < Set Value of [Ft-3.19]
Output </NEAR> signal
When [Ft-3.18] is set with high value during the low-speed
operation (less 100 [pps]), </P-COM> output signal remains ON.
•
</P-COM> and </NEAR> are sequence output signal. To use
</P-COM> and </NEAR> function, allocate </P-COM> and
</NEAR> signal and refer to the “Allocation Method for
Seqeunce Output Signal” on the 3-18 page.
0x2314
Range of Available Following Error
CSP
Setting Range
Size (Data Type)
Unit
Access
PDO Map
Attribute
Init Value
Ft-no
0~
2147483647
4 byte(UDINT)
pulse
RW
-
Always
655360
Ft-3.20
▶
RSWare : Drive - Faults - Following Error Limit
▶
It set the allowable range of position error. If the position error is bigger than this set
value, the E.019 (Position Error Limit Exceeded : E.PoSEr) fault occurs.
Note
Содержание OEMax CSD7
Страница 1: ...CSD7 Servo Drive User Manual Catalog Number s CSD7_ BN F 1 EtherCAT Network type ...
Страница 4: ......
Страница 12: ...viii CSD7 Servo Drive EtherCAT SAFETY FUNCTION CONNECTOR B 6 ...
Страница 23: ...Preface P 11 CSD7 Servo Drive EtherCAT ...
Страница 24: ......
Страница 33: ...Installation 2 5 CSD7 Servo Drive EtherCAT 100W 200W 400W 800W 1KW 1 5KW ...
Страница 38: ......
Страница 76: ......
Страница 94: ......
Страница 114: ......
Страница 126: ......
Страница 314: ......
Страница 320: ...A 6 Specification and Exterior Dimensions CSD7 Servo Drive EtherCAT FigureA 5 400W FigureA 6 800W 1 5KW ...
Страница 327: ...able and Connector Specification B 5 CSD7 Servo Drive EtherCAT ...
Страница 330: ......
Страница 331: ...Publication CSD7 UM001A Network EN October 2015 ...
Страница 332: ...Copyright 2015 RS Automation Co Ltd All rights reserved ...