2A3/4
2-2-7
4. Fixing section
• Jam in fixing section (jam code 40)
The eject switch (ESW) does not turn on within 2552 ms of the registration clutch (RCL)
turning on.
RCL
2552 ms
On
Off
On
Off
ESW
Timing chart 2-2-15
5. Eject section
• Jam in eject section (jam code 50)
The eject switch (ESW) does not turn off within 2528 ms of turning on.
2528 ms
On
Off
ESW
Timing chart 2-2-16
• Jam in switchback eject section (jam code 51)
The switchback eject switch (SBESW) does not turn off within 1470 ms of turning on.
1470 ms
On
Off
SBESW
Timing chart 2-2-17