3-2-86
2A3/4
Description
Maintenance
item No.
U345
Setting the value for maintenance due indication
Description
Sets when to display a message notifying that the time for maintenance is
about to be reached, by setting the number of copies that can be made
before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance
cycle and that of the maintenance count reaches the set value, the
message is displayed.
Purpose
To change the time to display the maintenance due indication.
Method
Press the print key. The current setting is displayed.
Setting
1
Change the setting using the numeric or Up/Down keys.
Initial setting: 0
2
Press the print key. The setting is set, and the screen for entering a
maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press
the stop/clear key. The screen for selecting a maintenance item is
displayed.
Description
Display period for the next maintenance
(remaining count before the end of the maintenance cycle)
Setting range
0 to 9999
Содержание Ri 4230
Страница 1: ...4230 5230 S M MCA SERVICE MANUAL Published in June 00 2A370941 Revision 1 Ri 4230 5230 Ri 4230 5230 ...
Страница 3: ...SERVICE MANUAL Ri 4230 5230 ...
Страница 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Страница 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Страница 21: ...1 1 7 2A3 4 CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1 ...
Страница 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Страница 119: ......
Страница 138: ......
Страница 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Страница 419: ...1 1 25 2A3 4 CONTENTS 3 5 Self Diagnosis 3 5 1 Self diagnosis 3 5 1 1 Self diagnostic function 3 5 1 ...
Страница 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...