2A3/4
3-6-7
Causes
Check procedures/corrective measures
1. Dirty or flawed transfer charger
wire.
2. Foreign matter in the developing
section.
3. Flawed drum.
4. Dirty shading plate.
Causes
Check procedures/corrective measures
1. Dirty contact glass.
2. Dirty or flawed drum.
3. Deformed or worn cleaning blade.
4. Dirty scanner mirror.
(5) A white line appears
longitudinally.
Causes
1. Dirty or flawed transfer charger wire.
2. Foreign matter in the developing section.
3. Flawed drum.
4. Dirty shading plate.
Clean the transfer charger wire or, if it is
flawed, replace it.
Check if the magnetic brush is formed
uniformly. If not, replace the developer.
Replace the drum (see page 3-3-45).
Clean the shading plate.
(6) A black line appears
longitudinally.
Causes
1. Dirty contact glass.
2. Dirty or flawed drum.
3. Deformed or worn cleaning blade.
4. Dirty scanner mirror.
Clean the contact glass.
Clean the drum or, if it is flawed, replace it
(see page 3-3-45).
Replace the cleaning blade (see page
3-3-59).
Clean the scanner mirror.
Содержание Ri 4230
Страница 1: ...4230 5230 S M MCA SERVICE MANUAL Published in June 00 2A370941 Revision 1 Ri 4230 5230 Ri 4230 5230 ...
Страница 3: ...SERVICE MANUAL Ri 4230 5230 ...
Страница 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Страница 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Страница 21: ...1 1 7 2A3 4 CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1 ...
Страница 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Страница 119: ......
Страница 138: ......
Страница 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Страница 419: ...1 1 25 2A3 4 CONTENTS 3 5 Self Diagnosis 3 5 1 Self diagnosis 3 5 1 1 Self diagnostic function 3 5 1 ...
Страница 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...