3-2-34
2A3/4
Description
Maintenance
item No.
3
Press the print key. The value is set.
4
To return to the screen for selecting an item, press the stop/clear key.
Interrupt copy mode
While this maintenance item is being performed, copying from an original
can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for
selecting a maintenance item No. is displayed.
U099
Checking and setting the original size detection sensor
Description
Checks the operation of the original size detection sensor and sets the
sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the
original size detection sensor malfunctions frequently due to incident light
or the like.
Start
1
Press the print key. The screen for selecting an item is displayed.
2
Select an item.
* The screen for executing each item is displayed.
Method to display the data for the sensor
1
Press the print key. The detection sensor transmission data is
displayed.
Figure 3-2-6
2
To return to the screen for selecting an item, press the stop/clear key.
U093
Display
DATA
B/W LEVEL
Description
Displaying detection sensor transmission data
Setting detection sensor threshold value
Setting original size judgment time
: 123 123 123
: 123 123 123
: 255 255 255
Rear of machine
Center of machine
Front of machine
Содержание Ri 4230
Страница 1: ...4230 5230 S M MCA SERVICE MANUAL Published in June 00 2A370941 Revision 1 Ri 4230 5230 Ri 4230 5230 ...
Страница 3: ...SERVICE MANUAL Ri 4230 5230 ...
Страница 13: ...4230 5230 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section ...
Страница 14: ...1 1 5 2A3 4 CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1 ...
Страница 21: ...1 1 7 2A3 4 CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1 ...
Страница 100: ...4230 5230 S M MCA ELECTRICAL SECTION II II Electrical Section ...
Страница 119: ......
Страница 138: ......
Страница 159: ...4230 5230 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION ...
Страница 419: ...1 1 25 2A3 4 CONTENTS 3 5 Self Diagnosis 3 5 1 Self diagnosis 3 5 1 1 Self diagnostic function 3 5 1 ...
Страница 448: ...2A3 4 3 6 3 25 Toner scatters at the leading edge of the image See page 3 6 17 ...