CALCulate<n>:TLINe<dl>:STATe
<State>
This command turns a time line on and off
Suffix:
<n>
.
<dl>
1 to 4
time line
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:TLIN:STAT ON
Turns the first time line on.
11.8.10
Defining Limit Checks
Note that in remote control, upper and lower limit lines are configured using separate
commands. Thus, you must decide in advance which you want to configure. The x-val-
ues for both upper and lower limit lines are defined as a common control line. This con-
trol line is the reference for the y-values for both upper and lower limit lines.
..........................................................................................901
............................................................................................ 911
Checking the Results of a Limit Check
................................................................. 914
Programming Example: Using Limit Lines
............................................................ 915
11.8.10.1
Configuring Limit Lines
CALCulate<n>:LIMit<li>:COMMent
.................................................................................. 902
CALCulate<n>:LIMit<li>:CONTrol[:DATA]
......................................................................... 902
CALCulate<n>:LIMit<li>:CONTrol:DOMain
........................................................................902
CALCulate<n>:LIMit<li>:CONTrol:MODE
..........................................................................903
CALCulate<n>:LIMit<li>:CONTrol:OFFSet
........................................................................ 903
CALCulate<n>:LIMit<li>:CONTrol:SHIFt
........................................................................... 904
CALCulate<n>:LIMit<li>:CONTrol:SPACing
...................................................................... 904
CALCulate<n>:LIMit<li>:LOWer[:DATA]
............................................................................904
CALCulate<n>:LIMit<li>:LOWer:MARGin
..........................................................................905
CALCulate<n>:LIMit<li>:LOWer:MODE
............................................................................ 905
CALCulate<n>:LIMit<li>:LOWer:OFFSet
...........................................................................905
CALCulate<n>:LIMit<li>:LOWer:SHIFt
..............................................................................906
CALCulate<n>:LIMit<li>:LOWer:SPACing
......................................................................... 906
CALCulate<n>:LIMit<li>:LOWer:STATe
.............................................................................906
CALCulate<n>:LIMit<li>:LOWer:THReshold
......................................................................907
........................................................................................907
......................................................................................... 908
Setting Basic Spectrum RF Measurement Parameters