The Spectrum Application (RF Measurements)
R&S
®
FPL1000
296
User Manual 1178.3370.02 ─ 09
For details, see
Chapter 7.3.3.1, "Basics on the Internal Generator"
............................................................................................... 297
................................................................................................297
Usage
Determines the type of signal provided by the internal generator:
●
on page 283: constant frequency and power level
●
on page 284: constant power level, frequency follows ana-
lyzer frequency (only available for frequency sweeps in the Spectrum application)
●
on page 284: constant frequency, linearly increasing power level
(only available in the Spectrum application)
Remote command:
SOURce<si>:FREQuency:COUPling[:STATe]
State
Enables or disables the internal generator. The generator signal is output at the GEN
Output
50
Ω
connector on the front panel.
Remote command:
Receiving Data Input and Providing Data Output