CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
851
User Manual 1173.9511.02 ─ 12
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Suffix:
<no>
.
1..200
The segment number must not exceed the total number of seg-
ments measured.
Return values:
<1_Reliability>
. In list mode, a zero reliability indicator indi-
cates that the results in all measured segments are valid. A non-
zero value indicates that an error occurred in at least one of the
measured segments.
<2_SegReliability>
0 | 3 | 4 | 8
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_EVMRMS>
<4_EVMPeak>
Error vector magnitude RMS and peak value.
Range:
0 % to 100 %
Default unit: %
<5_MErrRMS>
Magnitude error RMS value.
Range:
0 % to 100 %
Default unit: %
<6_MErrPEAK>
Magnitude error peak value.
Range:
-100 % to +100 % (AVERage: 0% to 100 %, SDE-
Viation: 0 % to 50 %)
Default unit: %
<7_PErrRMS>
Phase error RMS value.
Range:
0 deg to 180 deg
Default unit: deg
<8_PErrPeak>
Phase error peak value.
Range:
-180 deg to 180 deg (AVERage: 0 deg to 180 deg,
SDEViation: 0 deg to 90 deg)
Default unit: deg
<9_IQOffset>
I/Q origin offset
Range:
-100 dB to 0 dB
Default unit: dB
<10_IQImbalance>
I/Q imbalance
Range:
-100 dB to 0 dB
Default unit: dB
Command Reference