CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
570
User Manual 1173.9511.02 ─ 12
●
Continuous:
The measurement is continued until it is explicitly terminated; the
results are periodically updated.
●
Single-Shot:
The measurement is stopped after one statistics cycle.
Single-shot is preferable if only a single measurement result is required under fixed
conditions, which is typical for remote-controlled measurements. Continuous mode is
suitable for monitoring the evolution of the measurement results in time and observe
how they depend on the measurement configuration, which is typically done in manual
control. The reset/preset values therefore differ from each other.
Remote command:
CONFigure:CDMA:SIGN<i>:RXQuality:PSTRength:REPetition
Update Rate ← Pilot Strength
Sets the period of the "Pilot Strength" reporting in continuous mode. Softkey is also
available.
Remote command:
CONFigure:CDMA:SIGN<i>:RXQuality:PSTRength:URATe
Update Rate
Sets the update period of RLP and speech views. Softkey is also available.
Remote command:
CONFigure:CDMA:SIGN<i>:RXQuality:URATe
4.3.13.3
Limit Settings
This section defines limits for the results of the "RX Measurement FER".
The conformance test specification 3GPP2 C.S0043-0 specifies a variety of test cases
related to the FER limits. Adjust the value in accordance with your measurement.
Fig. 4-68: Limit settings
................................................................................................570
................................................................................... 571
FER FCH / FER SCH0
Configures limits for FER FCH and FER SCH0 measurements.
GUI Reference