1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
197
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:PNOFfset
.................................................. 197
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:CLRCode
.................................................. 197
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:SMASk
..................................................... 197
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:CNTCode
..................................................198
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:FORMat
.................................................... 198
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:ID:ANSI
.....................................................198
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:NPBits
...................................................... 198
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:IDOVerall?
................................................ 199
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:ID:MANual
.................................................199
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:PNOFfset
<PNOffset>
Defines the pilot PN offset index of the generated forward 1xEV-DO signal.
Parameters:
<PNOffset>
Range:
0 to 511
*RST:
0
Example:
See
Firmware/Software:
V1.0.15.0
V2.1.20: renamed from
CONFigure:EVDO:SIGNaling:NETWork:PROPerty:
PNOFfset
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:CLRCode
<CLRCode>
Defines the 8-bit color code of the sector.
Parameters:
<CLRCode>
Range:
0 to 255
*RST:
0
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:SECTor:SMASk
<SMask>
Defines the 8-bit sector subnet identifier.
Parameters:
<SMask>
Range:
0 to 128
*RST:
104
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation: