![Rohde & Schwarz CMW-KE100 Скачать руководство пользователя страница 673](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807673.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
673
User Manual 1173.9511.02 ─ 12
Parameters:
<BroadSlotCIndex>
Range:
0 to 7
*RST:
1
Example:
See
Firmware/Software:
V3.5.10
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:PCHannel:PRMS
<PageRegsiteredMS>
Specifies if non-registered mobile stations have to be paged.
Parameters:
<PageRegsiteredMS>OFF | ON
OFF
: the paging is sent to the registered and unregistered
mobile stations
ON
: the paging is sent only to the registered mobile stations
*RST:
ON
Example:
See
Firmware/Software:
V3.5.10
Manual operation:
See
4.5.9.6
Registration Setting
The following command configures the registration procedure.
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:TBASed
............................................. 673
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:DBASed
.............................................674
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:HOME
............................................... 674
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:FSID
..................................................675
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:FNID
................................................. 675
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:PUP
.................................................. 675
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:PDOWn
............................................. 676
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:PARameter
........................................ 676
CONFigure:CDMA:SIGN<i>:NETWork:REGistration:TBASed
<TimerBased>
Turns timer-based registration OFF/ON and/or defines the registration interval in sec-
onds.
A numeric value must be between 12.16 and 199515.84, inclusive; it will be rounded to
the closest value in
See
on page 553 for details.
Command Reference
深圳德标仪器
135-1095-0799