CONFigure:CDMA:SIGN<i>:NETWork:APRobes:PINCrement
<ProbeIncrement>
Defines the step size of power increases (PWR_STEP) between consecutive access
probes.
Parameters:
<ProbeIncrement>
Range:
0 dB to 7 dB
Increment: 0.5 dB
*RST:
3 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS810
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:PPSequence
<ProbPerSequence>
Defines the maximum number of access probes (NUM_STEP) contained in a single
access probe sequence.
Parameters:
<ProbPerSequence> Range:
1 to 16
*RST:
16
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS810
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:SPATtempt:RSP
<SequPerAttempt>
Maximum number of access probe sequences for an Access Channel or Enhanced
Access Channel response(MAX_RSP_SEQ).
Parameters:
<SequPerAttempt>
Range:
1 to 15
*RST:
1
Example:
See
Firmware/Software:
V1.0.15.0
V.2.1.20 Command renamed: ":RSP" appended
Manual operation:
See