1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
216
User Manual 1173.9511.02 ─ 12
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:FLPer:CLEVel
............................................... 216
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:RLPer:CLEVel
............................................... 216
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:PER:EVALuation
<LimitEvaluation>
Defines whether the limits specified for the forward and reverse link PER (Packet Error
Rate) measurements shall be evaluated per carrier or over all carriers. This only
affects multi-carrier evaluations.
Parameters:
<LimitEvaluation>
PERCarrier | ALLCarriers
*RST:
PERC
Default unit: %
Example:
See
Firmware/Software:
V2.1.20
Manual operation:
See
"Multi Carrier Limit Evaluation"
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:FLPer:MPER
<MaxPER>
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:RLPer:MPER
<MaxPER>
Defines an upper limit for the measured forward / reverse link PER (Packet Error
Ratio).
Parameters:
<MaxPER>
Range:
0 % to 100 %
*RST:
1 %
Default unit: %
Example:
See
Firmware/Software:
V2.1.20
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:FLPer:CLEVel
<MinConfidLevel>
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:RLPer:CLEVel
<MinConfidLevel>
Defines the minimum confidence level for the forward / reverse link PER measurement.
Parameters:
<MinConfidLevel>
Range:
0 % to 100 %
*RST:
95 %
Default unit: %
Example:
See
Firmware/Software:
V2.1.20
Manual operation:
See
Command Reference