1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
133
User Manual 1173.9511.02 ─ 12
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
FETCh:EVDO:SIGN<i>:PDATa:STATe?
Returns the state of the packet data (PPP) connection.
Return values:
<PDState>
OFF | ON | DORMant | CONNected
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KA100
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:PLSubtype?
Queries the active physical layer subtype, which in turn depends on the selected net-
work release (
CONFigure:EVDO:SIGN<i>:NETWork:RELease
):
●
with release 0 , the R&S
CMW uses subtype 0
●
with revision A, the R&S
CMW uses subtype 2
●
with revision B and more than 1 active carrier , the R&S
CMW uses subtype 3; oth-
erwise it uses subtype 2
Return values:
<PLSubtype>
ST01 | ST2 | ST3
Physical layer subtype 0/1, 2 or 3.
*RST:
ST2
Example:
See
Query Carrier Acquisition Status
Usage:
Query only
Firmware/Software:
V1.0.15.0
V2.1.20: Physical layer subtype 3 added
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CSTatus:IRAT?
Indicates whether an inter RAT handover is supported (as agreed during session nego-
tiation).
Currently this command doesn't return valid results.
Return values:
<InterRAT>
OFF
Command Reference
深圳德标仪器