![Rohde & Schwarz CMW-KE100 Скачать руководство пользователя страница 578](http://html.mh-extra.com/html/rohde-and-schwarz/cmw-ke100/cmw-ke100_user-manual_1477807578.webp)
CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
578
User Manual 1173.9511.02 ─ 12
CONFigure:CDMA:SIGN:RFSettings:FLFRequency?
CONFigure:CDMA:SIGN:RFSettings:RLFRequency?
CONFigure:CDMA:SIGN:RFSettings:FREQuency?
// *****************************************************************************
// Define power of base station signal and select AWGN mode and level.
// Query total power including AWGN.
// *****************************************************************************
CONFigure:CDMA:SIGN:RFPower:CDMA -50
CONFigure:CDMA:SIGN:RFPower:MODE:AWGN NORM
CONFigure:CDMA:SIGN:RFPower:LEVel:AWGN 0
CONFigure:CDMA:SIGN:RFPower:OUTPut?
// *****************************************************************************
// Query the signal to noise ratio while the AWGN is turned on.
// *****************************************************************************
CONFigure:CDMA:SIGN:RFPower:EBNT:FCH?
CONFigure:CDMA:SIGN:RFPower:EBNT:SCH?
// *****************************************************************************
// Configure power control of the MS: select the power control bits
// according to the "Pattern", select the step size and configure the segment
// bits and segment lenth for the continuous pattern execution. Start
// the power control. After the measurement switch off the pattern execution.
// *****************************************************************************
CONFigure:CDMA:SIGN:RPControl:PCBits PATT
CONFigure:CDMA:SIGN:RPControl:SSIZe 0.5
CONFigure:CDMA:SIGN:RPControl:REPetition CONT
CONFigure:CDMA:SIGN:RPControl:SEGMent1:BITS DOWN
CONFigure:CDMA:SIGN:RPControl:SEGMent2:BITS UP
CONFigure:CDMA:SIGN:RPControl:SEGMent1:LENGth 100
CONFigure:CDMA:SIGN:RPControl:SEGMent2:LENGth 100
CONFigure:CDMA:SIGN:RPControl:SEGMent3:LENGth 0
CONFigure:CDMA:SIGN:RPControl:SEGMent4:LENGth 0
CONFigure:CDMA:SIGN:RPControl:RUN ON
CONFigure:CDMA:SIGN:RPControl:RUN OFF
// *****************************************************************************
// Specify Open Loop Rule expected nominal power of the DUT and
// query the expected nominal power that the DUT has to transmit.
//
// Alternativelly set the expected power manually.
// *****************************************************************************
CONFigure:CDMA:SIGN:RFPower:EPMode OLRule
CONFigure:CDMA:SIGN:RFPower:EXPected?
Programming