Troubleshoot the Switch
Link Status
Verify that both sides have a network link. A broken wire or one shut down
port can cause one side to show a link, but not the other side. A Link status
indicator does not indicate that the cable is fully functional. The cable can
encounter physical stress that causes it to function at a marginal level. If the
Link status indicator for the port is not lit, do the following:
• Connect the cable from the switch to a known good device.
• Make sure that both ends of the cable are connected to the correct ports.
• Verify that both devices have power.
• Verify that you are using the correct cable type.
• Rule out loose connections. Sometimes a cable appears to be seated, but
is not. Disconnect the cable, and then reconnect it.
Transceiver Issues
Use only Rockwell Automation SFP modules on the switch. Each SFP module
has an internal serial EEPROM that is encoded with security information.
This encoding identifies and validates that the module meets the requirements
for the switch.
Check these items:
• Verify that the SFP module is valid and functional. Exchange a suspect
module with a known good module. Verify that the module is supported
on this platform.
• Use the CLI show interfaces command or the CLI show int status
command to verify the error-disabled or shutdown status of the port or
module. Re-enable the port if needed.
• Make sure that all fiber connections are properly cleaned and securely
connected.
Port and Interface Settings
A cause of port connectivity failure can be a disabled port. Verify that the port
or interface is not disabled or powered down for some reason. If a port or
interface is manually shut down on one side of the link or the other side, the
link does not come up until you re-enable the port. Use the CLI show
interfaces privileged EXEC command to verify the port or interface error-
disabled, disabled, or shutdown status on both sides of the connection. If
needed, re-enable the port or the interface.
Содержание ArmorStratix 5700 series
Страница 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Страница 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Страница 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Страница 156: ...156 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 5 Install Stratix 5700 Switches Notes...
Страница 370: ...370 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 7 Configure Switch Features...
Страница 407: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 407 Monitor the Switch Chapter 8...
Страница 409: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 409 Monitor the Switch Chapter 8...
Страница 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Страница 494: ...494 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix B Port Assignments for CIP Data Notes...
Страница 540: ...540 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix D Cables and Connectors Notes...
Страница 547: ......