Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
125
Install Stratix 5410 Switches
Chapter 4
To connect a device to a 10/100/1000 Ethernet, PoE/PoE+ port, follow these
steps.
1. Choose one of these options:
• If the auto-MDIX feature is enabled, connect either a crossover or
straight-through cable to an RJ45 connector on the front panel. The
default setting for auto-MDIX is enabled.
• If auto-MDIX is disabled, use the following guidelines to choose the
cable for connecting the 10/100/1000Ethernet ports to other
devices.
2. Connect the other end of the cable to an RJ45 connector on the other
device.
The port status indicator turns on when both the switch and the
connected device have an established link.
The port status indicator is amber while Spanning Tree Protocol (STP)
discovers the topology and searches for loops. This process can take as
long as 30 seconds, and then the Port status indicator turns green.
The following conditions can prevent the Port status indicator from
turning On:
• The device at the other end is not turned On.
• A problem exists with a cable or the adapter that is installed in the
attached device.
3. Reconfigure and restart the connected device if necessary.
4. To connect another device, repeat this procedure.
Device
Crossover Cable
(1)
(1) 100BASE-TX and 1000BASE-T traffic requires twisted four-pair, Category 5, Category 5e, or Category 6 cable. 10BASE-T traffic
uses Category 3 or Category 4 cable.
Straight-through Cable
Switch to switch
Yes
No
Switch to hub
Yes
No
Switch to computer or server
No
Yes
Switch to router
No
Yes
32561-M
Содержание ArmorStratix 5700 series
Страница 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Страница 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Страница 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Страница 156: ...156 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 5 Install Stratix 5700 Switches Notes...
Страница 370: ...370 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 7 Configure Switch Features...
Страница 407: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 407 Monitor the Switch Chapter 8...
Страница 409: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 409 Monitor the Switch Chapter 8...
Страница 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Страница 494: ...494 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix B Port Assignments for CIP Data Notes...
Страница 540: ...540 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix D Cables and Connectors Notes...
Страница 547: ......