Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
67
Kinetix 2000 Multi-axis Servo Drives
Power Dissipation Specifications
Use this table to size an enclosure and calculate required ventilation for your Kinetix 2000 drive system.
Weight Specifications
Kinetix 2000 Modules
Usage as % of Rated Power Output (watts)
20%
40%
60%
80%
100%
Integrated Axis Module (IAM Converter)
(1)
(1) Internal shunt power is not included in the calculations and must be added based on utilization.
2093-AC05-MP1
Three-phase input
7.0
10.5
14.0
17.4
20.9
2093-AC05-MP2
2093-AC05-MP5
2093-AC05-MP1
Single-phase input
5.8
8.0
10.3
12.6
14.8
2093-AC05-MP2
2093-AC05-MP5
Integrated Axis Module (IAM Inverter) or Axis Module (AM)
2093-AC05-MP1 or 2093-AMP1
31.6
33.6
35.6
37.6
39.6
2093-AC05-MP2 or 2093-AMP2
33.0
36.4
39.8
43.3
46.8
2093-AC05-MP5 or 2093-AMP5
36.2
42.9
49.8
56.8
63.9
2093-AM01
38.3
46.7
55.3
64.1
73.1
2093-AM02
44.3
55.6
67.3
79.2
91.4
Shunt Module
2093-ASP06
35.8
45.8
55.8
65.8
75.8
Kinetix 2000 Module Cat. No.
Weight, approx
kg (lb)
Kinetix 2000 Module Cat. No.
Weight, approx
kg (lb)
IAM
2093-AC05-MP1
1.32 (2.9)
Power Rails
(Slim)
2093-PRS1
0.27 (0.6)
2093-AC05-MP2
2093-PRS2
0.38 (0.8)
2093-AC05-MP5
2093-PRS3
0.51 (1.1)
AM
2093-AMP1
0.67 (1.5)
2093-PRS4
0.64 (1.4)
2093-AMP2
2093-PRS5
0.77 (1.7)
2093-AMP5
2093-PRS7
1.03 (2.3)
2093-AM01
0.95 (2.1)
2093-PRS8S
1.28 (2.8)
2093-AM02
Shunt module
2093-ASP06
0.59 (1.3)
Slot-filler module
2093-PRF
0.15 (0.3)