114
Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
Common Accessories
Line Interface Modules
The Bulletin 2094 line interface module (LIM) is designed to replace many of the common input power devices required for your servo drive system.
By using the LIM module, you save panel space and reduce the amount of wiring when compared with individual components mounted separately.
In this example, the 2094-BL
xx
S module is compared to a similar configuration of discrete components. Auxiliary and control power (230V) is
developed from the LIM module three-phase input power.
Comparing the LIM Module with Discrete Components (catalog number 2094-BL
xx
S)
An example comparing the 2094-AL
xx
S module to discrete components would be similar to the example above, but with 230V three-phase input
power and without the 460V to 230V step-down transformer.
Examples comparing the 2094-AL09 and 2094-BL02 modules to discrete components would also be similar to the examples above and include the
features that apply to those models.
Drive/LIM Module Compatibility
Drive Family
Drive Cat. No.
Compatible LIM Module Cat. No.
Kinetix 2000
2093-AC05-M
xx
2094-AL
xx
S, 2094-XL75S-C2, 2094-AL09
Kinetix 6200/
Kinetix 6500
2094-BC
xx
-M
xx
-M
2094-BL
xx
S, 2094-BL02, 2094-XL75S-C
x
Kinetix 6000
2094-
x
C
xx
-M
xx
-S
2094-AL
xx
S, 2094-AL09, 2094-BL
xx
S, 2094-BL02, 2094-XL75S-C
x
Kinetix 7000
2099-BM06-S, 2099-BM07-S, 2099-BM08-S
2094-BL75S
TM
TM
Line Interface Module
(2094-BL
xx
S)
• Compact, Cost-effective
• Reduced Labor for Design, Panel
Layout, and Mounting
• Extra Filtering
• Safety Contactor
• 230V Auxiliary/Control Power
• Factory Tested
Components require
more time for:
• Panel Layout/Design
• Sizing the System
• Making 100 Wire Terminations
• Mounting 9+ Components
• Testing
Circuit Breaker
(CB3)
Circuit Breaker
(CB1)
Circuit Breaker
(CB2)
Fuse Block
Disconnect
Safety Contactor
Three-phase
Line Input (400V-class)
Three-phase
Line Input (400V-class)
Single-phase
Single Stage,
Line Filter (230V)
24V DC
Power Supply
Three-phase
Single Stage,
Line Filter
Contactor
Control and
Status I/O
Auxiliary
Power Output
(24V DC) to:
Motor Brake
other
Auxiliary
Power Output
(230V) to:
PLC
HMI
other
I/O
Power Output
(24V DC) to:
Sensors
PLC
other
Control
Power Output
to Drive
(230V AC)
Three-phase
Power Output
to Drive
(460V AC)
AC Line
Filter
Kinetix MPL
Motor
Photoelectric
Sensors
ControlLogix
Chassis
PanelView™ Plus
Terminal
Contactor
Control and
Status I/O
Auxiliary
Power Output
(24V DC) to:
Motor Brake
other
Auxiliary
Power Output
(230V) to:
PLC
HMI
other
I/O
Power Output
(24V DC) to:
Sensors
PLC
other
Control
Power Output
to Drive
(230V AC)
Three-phase
Power Output
to Drive
(460V AC)
AC Line
Filter
Kinetix MPL
Motor
Photoelectric
Sensors
Kinetix 6000, Kinetix 6200,
Kinetix 6500, or
Kinetix 7000 Drives
ControlLogix
Chassis
PanelView Plus
Terminal
460V to 230V
Transformer
Kinetix 6000, Kinetix 6200,
Kinetix 6500, or
Kinetix 7000 Drives