156
Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
Kinetix 2090 Interface Cables
Sercos interface Fiber-optic Cable Dimensions
RBM Module Interface Cable Dimensions
Fiber-optic Cable
Cat. No.
A
mm (in.)
B
mm (in.)
BR
(1)
mm (in.)
(1) Standard (non-flex) cables have a regular maintenance and installation bend radius of 10 times (10x) the cable diameter.
C
mm (in.)
D
mm (in.)
2090-SCEP
x-x
7 (0.27)
25 (1.0)
25 (1.0)
10 (0.39)
2.2 (0.09)
2090-SCNP
x-x
2090-SCVP
x-x
40 (1.6)
5.0 (0.2)
2090-SCVG
x-x
30 (1.2)
RBM Module Cable
Cat. No.
A
mm (in.)
B
mm (in.)
C
mm (in.)
D
mm (in.)
E
mm (in.)
F
mm (in.)
G
mm (in.)
H
mm (in.)
2090-XXNRB-10F0P5
517 (20.3)
115 (4.5)
50 (1.9)
16 (0.6)
120 (4.7)
74 (2.9)
16 (0.6)
16 (0.63)
2090-XXNRB-8F0P6
619 (24.4)
74 (2.9)
19 (0.75)
D
A
C
B
BR
Cable Diameter
Connector
Diameter
Start of
Bend Radius
Dimensions are in mm (in.)
(reference only)
23.5 (0.9)
9.6 HEX.
7.1 (0.3)
3.2 (0.1)
Panel Cutout
Bulkhead Adapter Dimensions (2090-S-BLHD)
RBM
Drive
A
B
C
D
E
F
G
H
Dimensions are in mm (in.)
(reference only)