Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
57
Kinetix 3 Component Servo Drives
Fuse/Contactor Specifications
Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for branch circuit protection.
The following fuse examples are recommended for use with Kinetix 3 drives.
Power Dissipation Specifications
Use this table to size an enclosure and calculate required ventilation for your Kinetix 3 drive system.
Weight Specifications
Fuse and Contactor Specifications
Drive Cat. No.
AC Input Power
(1)
(2)
(3)
Recommended Fuse
(1) Fuses specified are Bussmann fuses.
(2) FNQ-R fuses are described as time-delay fuses, Class CC.
(3) LPJ fuses are described as dual-element time-delay fuses, Class J.
Control Power
(4)
Recommended Fuse
(4) FRS-R fuses are described as dual-element time-delay fuses, Class RK5.
Contactor
(5)
(5) For contactors:
x
represents coil voltage,
y
represents the number of contacts.
2071-AP0
FNQ-R-7
FRS-R-2-1/2
FNQ-R-7-1/2
LPJ-6
100-K05
xy
2071-AP1
2071-AP2
100-K09
xy
2071-AP2
FNQ -R-10
100-K12
xy
2071-AP8
FNQ-R-20
LPJ-20
100-C16
xy
2071-A10
2071- A15
FNQ-R-30
LPJ-30
100-C23
xy
Drive Cat. No.
Usage as % of Rated Power Output
(watts)
20%
40%
60%
80%
100%
2071-AP0
19.3
20.0
20.6
21.3
22.0
2071-AP1
20.1
21.6
23.1
24.6
26.2
2071-AP2
21.7
24.6
27.6
30.6
33.7
2071-AP4
25.6
31.9
38.4
45.2
52.2
2071-AP8
26.4
32.3
38.6
45.1
52.0
2071-A10
30.9
40.2
50.1
60.5
71.5
2071-A15
37.4
50.1
63.8
78.4
93.9
Drive Cat. No.
Weight, approx
kg (lb)
2071-AP0
0.70 (1.5)
2071-AP1
0.75 (1.6)
2071-AP2
2071-AP4
1.0 (2.2)
2071-AP8
1.75 (3.9)
2071-A10
2071-A15