106
Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
Common Accessories
Shunt Power Example for Kinetix 6000 Drives (without external shunt)
Shunt Power Example for Kinetix 6200 or Kinetix 6500 Drives (without external shunt)
Dimensions - Bulletin 2094 Shunt Module
Modules are shown mounted to the power rail and the dimensions reflect that. For replacement connector set catalog number, refer to Connector
.
IMPORTANT
When the 2094-BSP2 shunt module is wired to a Bulletin 1394 external shunt module, the IAM/AM (internal shunt) and
2094-BSP2 shunt module is disabled and the continuous shunt power is equal to that of the external shunt module alone.
Kinetix 6000 (400V-class) Shunt Power Example
400 W Continuous Shunt Power
2094-BSP2 shunt module, 200 W
2094-BMP5-S AM module, 50 W internal shunt
2094-BM01-S AM module, 50 W internal shunt
2094-BM01-S AM module, 50 W internal shunt
2094-BC02-M02-S IAM module, 50 W internal shunt
Kinetix 6200/Kinetix 6500 (400V-class)
Shunt Power Example
400 W Continuous Shunt Power
2094-BSP2 shunt module, 200 W
2094-BMP5-M AM power module, 50 W internal shunt
2094-BM01-M AM power module, 50 W internal shunt
2094-BM01-M AM power Module, 50 W internal shunt
2094-BC02-M02-M IAM power module, 50 W internal shunt
263
(10.3)
70
(2.76)
256
(10.1)
249
(9.8)
123
(4.8)
287
(11.3)
Dimensions are in mm (in.)
Bulletin 2094
Power Rail
2094-BSP2
Shunt Module