Rockford Systems, LLC
64
Call: 1-800-922-7533
SSC-1500 Part Revolution Solid-State Control
SECTION 4—PROGRAMMING
AUXILIARY OUTPUT
The SSC-1500 press control provides one (1) auxiliary output relay that has two contacts which are fused for 4 A @ 115 V. When this auxiliary output
is set to be on, it can be programmed to change state whenever any or all of the following stop conditions occur: the batch counter setting is reached,
a fault condition occurs, the press stops, or the press emergency stops. The output contacts can be programmed either N.O. (normally open) or
N.C. (normally closed).
This auxiliary output can be tied in to a PLC (programmable logic controller) that’s being used to control auxiliary equipment for the press, such as a
feeder, robot, or indexing table. This way, the auxiliary equipment will know when the press has stopped, and can be programmed to stop as well.
The output can also be used for something as simple as turning an indicator light on or off or sounding an audible alarm. Programming choices can
be either OFF or ON.
1. Aux Out Batch Count:
With this function turned on, the auxiliary
output contacts will change state when the batch counter setting is
reached. The programming choices are OFF or ON.
2. Aux Out Fault:
With this function turned on, the auxiliary output
contacts will change state when a fault occurs. The programming
choices are OFF or ON.
3.
Aux Out Stop:
With this function turned on, the auxiliary
output contacts will change state when the machine stops. The
programming choices are OFF or ON.
4. Aux Out E-Stop:
With this function turned on, the auxiliary output
contacts will change state when the machine is emergency stopped.
The programming choices are OFF or ON.
5. Aux Out Logic:
This setting is used to change the logic that
activates the output. The programming choices are N.O. (normally
open) or N.C. (normally closed).
HOW TO PROGRAM THE AUXILIARY OUTPUT
Select the
ON
position of the program OFF/ON selector switch. One of
the MAIN PROGRAM SCREENS will be displayed.
On the MAIN PROGRAM SCREEN, use
↓
and
↑
on the keypad to scroll
through the program options. Press
ENTER
when the pound symbol
(#) is next to AUXILIARY OUTPUT. The security code screen will be
displayed. See Figure 4.64. You will be prompted to enter the security
code.
Press ESC to stop and return to the MAIN PROGRAM SCREEN. Press
BKSP
to backspace or press
CLR
to delete the entry and start over.
Press
ENTER
when finished.
After the correct security code has been entered, the FIRST
PROGRAMMABLE PARAMETERS SCREEN will be displayed.
See Figure 4.65.
Figure 4.64
Security Code Screen
ENTER SECURITY CODE
_ CODE
Figure 4.65
First Programmable Parameters Screen
>Aux Out Batch Count
Aux Out Fault
Aux Out Stop
Aux Out E-Stop
PROGRAMMABLE PARAMETERS FOR THE AUXILIARY OUTPUT
(Continued on next page.)