SSC-1500 Part Revolution Solid-State Control
SECTION 7—MAINTENANCE AND INSPECTION
Air System
1.
Be sure to turn the air pressure off, bleed air from the system or component, and lockout before maintaining any air equipment.
2.
Inspection of the entire air system is dependent on the frequency of machine operation and the cleanliness of the plant air lines. Both free
moisture and solids should be removed automatically by the air filter. Be sure to drain the filter bowl whenever the water level in the sump reaches
the lower baffle. To remove the filter element for cleaning, shut air line down and exhaust pressure. See Filter-Regulator-Lubricator Installation
Manual No. KSL-208 and page 24 of this manual.
3.
Be sure to check the lubricator for proper oil level and oil delivery adjustment. See Installation Manual No. KSL-208.
4.
The monitored dual solenoid air valve that operates the clutch and releases the brake must be protected from foreign material getting into the
valve. The valve relies on the performance of the air filter. The valve’s exhaust muffler must be removed regularly and cleaned so dumping of air
is unrestricted. Refer to Installation Manual Nos. KSL-036 or KSL-037 and page 24 of this manual.
The maintenance and inspection sections in this manual cannot be all-inclusive. Always refer to the original
equipment manufacturer’s maintenance manuals or the machine owner’s manual. If you do not have an
owner’s manual, contact the machine manufacturer.
Care of the Keypad/Display
To clean the keypad/display, use a clean soft cloth with soap and warm water, but do not saturate. Do not use oily rags, solvents, or
ammonia-based glass cleaner.