![Rockford Systems SSC-1500 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303017.webp)
Rockford Systems, LLC.
Call: 1-800-922-7533
17
SSC-1500 Part Revolution Solid-State Control
SECTION 3—INSTALLATION OF COMPONENTS
SSC-1500 Control Module
Assembly
Photo 3.9
Inside View of Standard Control Box
STANDARD CONTROL BOX
The standard control box (20” x 20” x 8”) is furnished with the keypad/display, program
OFF/ON selector switch, and other selector switches on the front of the enclosure door. This
NEMA 12 enclosure contains the control module assembly, master control relay, primary
multi-tap transformer, and terminal strips. A standard box with a plain door is also available
for use with a remote operator station.
Photo 3.8
Standard Control Box
Multi-Tap
Transformer
Master Control
Relay
CUSTOM CONTROL BOX
A custom control box contains the standard control module and
components described above plus the following:
• main power disconnect switch
• main drive motor starter
• ram adjust motor starter (if furnished)
This NEMA 12 enclosure will vary in size based on the size of the
disconnect switch and motor starter components. The enclosure
contains the disconnect switch, main motor starter, ram adjust
motor starter (if furnished), clutch/brake control module, master
control relay, primary multi-tap transformer, and terminal strips. The
keypad/display, selector switches, motor controls, and disconnect
switch handle may have been furnished on the door of the
enclosure, or furnished as a plain door enclosure for use with a
remoter operator station.
Photo 3.10
Plain Door Custom Control Box with Remote Operator Station
(Continued on next page.)