![Rockford Systems SSC-1500 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303075.webp)
Rockford Systems, LLC.
Call: 1-800-922-7533
75
SSC-1500 Part Revolution Solid-State Control
SECTION 8—REPLACEMENT PROCEDURES
All power to the machine must be off before
replacing the battery or any other parts.
1.
Remove the control module from the control box
(steps 1 - 3 on page 74).
2.
Remove the top cover plate from the SSC-1500 control module by
removing the four small screws.
3.
Locate fuses F1 - F6. Grasp the faulty fuse and pull straight up.
4.
Insert the new fuse by lining up the pins with the holes on the
circuit board.
5.
Replace the cover plate back on the control module and secure it
with the four screws.
6.
Put the control module back in place, tighten the Allen-head bolts,
plug in the main power cord, and insert all terminal strips.
Be careful when placing the cover back onto the
module. The op amp must remain in its original 45°
position (see Photo 8.9).
All power to the machine must be off before
replacing the battery or any other parts.
1.
Remove the control module from the control box
(steps 1 - 3 on page 74).
2.
Locate the main power ON/OFF switch on the left side of the control
module. Insert a small screwdriver in the slot just above the three
prongs and lift up (see Photo 8.10). The fuse holder should pop out.
3.
Locate and unclip the faulty fuse(s). Insert a new fuse. See Photo
8.11. Snap the fuse holder back into the main power ON/OFF switch.
4.
Put the control module back in place, tighten the Allen-head bolts,
plug in the main power cord, and insert all terminal strips.
Replacing Fuses F1 - F6
Replacing the Main Power Fuses
Photo 8.10
Photo 8.11
Photo 8.9
(Continued on next page.)
Op Amp