![Rockford Systems SSC-1500 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303040.webp)
Rockford Systems, LLC
40
Call: 1-800-922-7533
SSC-1500 Part Revolution Solid-State Control
SECTION 4—PROGRAMMING
Power-Up Procedure
After completing the installation of the control box and control
components, the SSC-1500 press control system must be initially
programmed according to the flowchart in Figure 4.1 on page 39 to get
the machine up and running. Before programming, the control must
first be powered up.
Turn the main power disconnect switch for the control to the
ON
position and start the main motor. The current main CPU software
version is displayed on the WAKE UP SCREEN. See Figure 4.2. If
safeguards are in place, press
YES
on the keypad and proceed.
Main Run Screen Overview
The MAIN RUN SCREEN displays the crankshaft angle (in degrees),
speed of the press (in SPM), batch counter, total counter, mode of
operation, and stop time (in milliseconds). See Figure 4.3.
The MAIN RUN SCREEN will be displayed whenever
ON
is selected on
the program OFF/ON selector switch.
When
OFF
is selected on the mode selector switch, the control will
not allow the machine to run and the CONTROL OFF SCREEN will be
displayed. See Figure 4.4.
Figure 4.2
Wake Up Screen
Figure 4.3
Main Run Screen
ANGLE 288
SPM 122
B-0000123 T-0040021
SINGLE S/T-188
Angle of
Crankshaft
Batch Counter
Mode of
Operation
Speed of Press
Total Counter
Stop Time
Figure 4.4
Control Off Screen
OFF
BKSP
0
YES
9
8
7
6
5
4
3
2
1
ESC
NO
.
CLR
ENTER
SSC-1500
PRESS CONTROL
VERSION - 1.00
SAFEGUARDS IN PLACE?