![Rockford Systems SSC-1500 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303020.webp)
Rockford Systems, LLC
20
Call: 1-800-922-7533
SSC-1500 Part Revolution Solid-State Control
SECTION 3—INSTALLATION OF COMPONENTS
CONTROL MODULE ASSEMBLY
(continued)
If necessary, the cover of the module can be taken off by removing the screws on the corners and pulling the top straight off. The dual CPU circuit
board is then exposed as shown in the photo below.
Photo 3.15
Top View of Control Module without Cover
Solenoid and PLS Relay Valve
Outputs (Terminal P6)
24-V DC Control
Inputs
(Terminal P8)
Battery Backup
Keypad/Display
(Terminal P4)
Fuse (F2)
Fuse (F1)
Fuse (F3)
Fuse (F4)
Fuse (F5)
Fuse (F6)
Auxiliary Output
(Terminal P7)
Core Module
Resolver
(Terminal P5)
User-serviceable parts on the dual CPU board are the core module, the battery, and the fuses. F1 and F2 fuses are for circuit protection of the S1
and S2 (solenoid). F3 and F4 fuses are for circuit protection for K2 and K3. F5 and F6 fuses are for circuit protection of the auxiliary output relay.
MPF1 and MPF2 fuses are the main power supply fuses (see photo 3.7 on page 16).
If any changes to the circuit boards are required, instructions will be sent with the new parts. See Section 8—Replacement Procedures for instructions
on replacing the core module, fuses, and battery.
Network Port
(Terminal P3)
Op Amp