SSC-1500 Part Revolution Solid-State Control
SECTION 2—INTRODUCTION
OTHER ELECTRICAL INTERLOCKS
There are basically two types of electrical interlocks as applied to machine control circuitry:
• Interlocks for the purpose of personnel protection, as explained on page 7.
• Interlocks intended for the purpose of protecting the machine and its control components.
There are other locations for interlocks that, when opened, prevent all machine functions. Examples of these types of interlocks are safety block
electrical cut-off systems, lubricating systems, die protection equipment, and tonnage monitoring systems.
Be sure to connect the various electrical interlocks to the proper terminals, in the control box, according to the machine wiring schematics. If your
schematics do not include these electrical interlocks, please send this information to the factory and they can be added to your drawings. There is an
additional charge for this service.
General Features of the SSC-1500 Control
• Redundant/Cross-Checking Microprocessors
• Redundant Microprocessor Logic Power Supplies
• Triple-Redundant Solid-State Solenoid Relays
• 4-Line x 20-Character LCD (Liquid Crystal Display) with 20-Key Operator Interface
• Absolute Resolver/Pulser with Sync Sensor for Timing and Motion Detection
• Wide Range of Input Power Supply—85 to 135 V AC
• Time-Based Brake Monitor with Programmable Warning and Fault Setpoints
• 6 User-Programmable 24-V DC Static Diagnostic or Die Protection Inputs
• 2 User-Programmable 24-V DC Cyclic Die Protection Inputs
• 7-Digit Total Counter and 7-Digit Batch Counter with Preset
• Light Curtain(s) Interface with OFF/ON Selector Switch
• 2 PLS (Programmable Limit Switch) Outputs—On/Off Angle, Timed Off, or Counted Output
• 2 PLS (Programmable Limit Switch) Outputs—On/Off Angle, Timed Off, or Counted Output
• 1 Auxiliary Output with 2 Contacts
• In formation Displayed when the machine is in Operation—Angle, Speed,
Batch Counter, Total Counter, Mode of Operation, and Stop Time
(Continued on next page.)
MODES OF OPERATION
• Two-Hand Inch (Regular or Timed)
• Two-Hand Single Stroke
• Foot Single Stroke
• Two-Hand “Walk-Away” Continuous
• Continuous-On-Demand
• Automatic Single Stroke
• Two-Hand-Maintained Continuous
• Foot-Maintained Continuous
• One-Hand or Foot Trip Single Stroke (Use with light curtain only)