![Rockford Systems SSC-1500 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303018.webp)
Rockford Systems, LLC
18
Call: 1-800-922-7533
SSC-1500 Part Revolution Solid-State Control
SECTION 3—INSTALLATION OF COMPONENTS
REMOTE OPERATOR-STYLE CONTROL BOXES
Remote operator-style control boxes include the same features and modes of operation as the standard control box described on page 17.
However, they do not have a control transformer.
These controls are for applications where the machine’s existing magnetic motor starter,
fused disconnect switch, and
control transformer
meet the safety requirements and can be reused. If the existing control transformer cannot be
reused or a new control transformer is required, contact the factory.
The three remote operator-style control boxes available have the keypad/display and all
operators on the door of the 16” x 16” x 8” enclosure. The remote operator-style control
boxes available are:
Style X
— Standard SSC-1500 control box without the control transformer
Style Y
— Standard SSC-1500 control box without the control transformer, but with an
e-stop, top-stop, and prior-action push button in the enclosure
Style Z
— Standard SSC-1500 control box without the control transformer, but with an
e-stop, top-stop, and prior-action push button, and two (2) guarded run/inch
buttons on the sides of the enclosure
CONTROL MODULE KIT
PART NO. PRC-000-KA
When a control module kit is furnished, it is supplied without the control enclosure, panel,
control transformer, control fuse, terminal strips, wire duct, and wiring. This control module
kit includes the control module, master control relay, shock mounts, fasteners, suppressors,
danger labels, and electrical prints. The minimum area required to install this kit on an existing
control panel is 14” x 12” x 5”. The electrical prints supplied with this kit show typical wiring
and all dimensions.
KEYPAD/DISPLAY KIT
PART NO. LLD-1513
When a keypad/display kit is furnished for use with any of the control boxes or control
module kit, it includes the keypdad/display with or without plate mount, a screen label,
a program OFF/ON selector switch, a light curtain OFF/ON selector switch, a hand/foot
selector switch, a mode selector switch, and 25’ of cable. Additional push buttons and
nameplates for motor starters, etc., may have been furnished depending on the features
required.
Photo 3.11
Style Z Remote Operator Control Box
Photo 3.13
(Continued on next page.)
Photo 3.12