SSC-1500 Part Revolution Solid-State Control
SECTION 4—PROGRAMMING
HOW TO PROGRAM USER INPUTS 1 - 6
(continued)
Use
↓
and
↑
on the keypad to scroll through the user inputs. If you
press
↓
when the arrow symbol (>) is next to INPUT #4, the second
USER INPUTS SCREEN will be displayed. See Figure 4.10. Press
ENTER
when the arrow symbol (>) is next to the user input you want
to program. The PROGRAMMABLE PARAMETERS SCREEN shown in
Figure 4.11 will be displayed.
Use
↓
and
↑
on the keypad to scroll through the programmable
parameters. Press
ENTER
when the double arrow symbol (>>) is next
to the parameter you want to program. A screen similar to the one
shown in Figure 4.12 will be displayed.
Once you are in the programming screen of the parameter you want to
program, use
↓
and
↑
on the keypad to reach the setting you desire
for that parameter. Press
ENTER
to finish.
Press
ESC
to return to the MAIN PROGRAM SCREEN.
Note: The appropriate user input terminals in the control box must be
wired so they correspond to the assigned fault messages. If the
order of the messages is changed or if other fault messages
are assigned, the connections to the terminal strip must also be
rearranged to reflect the changes.
Figure 4.11
Programmable Parameters
>>Logic
Stop Type
Message
Figure 4.12
Example of a Programming Screen
PROGRAMMING:
Input #1 Logic
OFF
Figure 4.10
Second User Inputs Screen
>Input #5
Input #6
Input #7 (cyclic)
Input #8 (cyclic)
(Continued on next page.)