![Rockford Systems SSC-1500 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303051.webp)
Rockford Systems, LLC.
Call: 1-800-922-7533
51
SSC-1500 Part Revolution Solid-State Control
SECTION 4—PROGRAMMING
HOW TO RUN THE REFERENCE CYCLE
(continued)
After the correct security code has been entered, the SYSTEM SETUP
SCREEN will be displayed. See Figure 4.31.
Use
↓
and
↑
on the keypad to scroll up and down. Press
ENTER
when
the arrow symbol (>) is next to Reference Cycle. The Reference Cycle
Instructions Screen will be displayed. See Figure 4.32. Press
YES
to
run a reference cycle, then cycle the press. A screen similar to the one
shown in Figure 4.33 will be displayed.
Press
ESC
when finished to return to the SYSTEM SETUP SCREEN.
Press
ESC
again to return to the MAIN PROGRAM SCREEN.
HOW TO RESTORE FACTORY DEFAULT SETTINGS
Select the
ON
position of the Program OFF/ON selector switch. One of
the MAIN PROGRAM SCREENS will be displayed.
On the MAIN PROGRAM SCREEN, use
↓
and
↑
on the keypad the to scroll
through the program options. Press
ENTER
when the pound symbol (#) is
next to SYSTEM SETUP. The security code screen will be displayed. See
Figure 4.34. You will be prompted to enter the security code.
Press
ESC
to stop and return to the MAIN PROGRAM SCREEN. Press
BKSP
to backspace or press
CLR
to delete the entry and start over.
Press
ENTER
when finished.
After the correct security code has been entered, the SYSTEM SETUP
SCREEN will be displayed. See Figure 4.35.
Use
↑
and
↑
on the keypad to scroll up and down. Press
ENTER
when the arrow symbol (>) is next to Restore Defaults. The RESTORE
DEFAULTS SCREEN will be displayed. See Figure 4.36.
Press
YES
to confirm and the factory default settings will be restored.
See page 66 for the factory default settings.
Press
ESC
when finished to return to the MAIN PROGRAM SCREEN.
Figure 4.31
System Setup Screen
>Reference Cycle
Restore Defaults
Security Code
Network Settings
Figure 4.32
Reference Cycle Instructions Screen
PRESS MUST BE AT TOP
SYNC EYE MUST BE OFF
PRESS YES TO START.
PRESS NO TO ABORT
Figure 4.36
Restore Defaults Screen
RESTORE DEFAULTS?
ARE YOU SURE
Press: YES or NO
Figure 4.34
Security Code Screen
ENTER SECURITY CODE
_ CODE
Figure 4.35
System Setup Screen
Reference Cycle
>Restore Defaults
Security Code
Network Settings
Figure 4.33
Sample of Completed Reference Cycle Screen
REFERENCE COMPLETE
SYNC ON:
158 deg
SYNC OFF:
202 deg
MOTION REF: