![Rockford Systems SSC-1500 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/rockford-systems/ssc-1500/ssc-1500_installation-manual_1474303076.webp)
Rockford Systems, LLC
76
Call: 1-800-922-7533
SSC-1500 Part Revolution Solid-State Control
All power to the machine must be off before
replacing the battery or any other parts.
1.
Remove the control module from the control box (steps 1 - 5 on
page 74).
2.
Remove the top cover plate from the SSC-1500 control module by
removing the four screws.
3.
Locate the battery on the control module. See Photo 8.12. Carefully
lift the battery clip up and remove the battery.
4.
Insert the new battery.
5.
Put the cover plate back onto the control module and secure it with
the four screws.
6.
Put the control module back in place, tighten the Allen-head bolts,
plug in the main power cord, and insert all terminal strips.
Note: When the battery fails or has been removed, all programmable
information will return to factory defaults (see page 66). All user
inputs will need to be reprogrammed.
Be careful when placing the cover back onto the
module. The op amp must remain in its original 45°
position (see Photo 8.13).
Replacing the Battery
Photo 8.12
Battery Clip
Battery
Photo 8.13
Op Amp
SECTION 8—REPLACEMENT PROCEDURES