14
IMS01J02-E4
2. SPECIFICATIONS
Basic functions
Data supervision:
Operating and system data
Control unit diagnosis:
Function modules configuration check
Self-diagnostic:
Check item: ROM/RAM check
Watchdog
timer
Power supply monitoring
If error occurs in self-diagnosis, the hardware will automatically
return the module outputs to the OFF position.
Memory backup:
Lithium battery for RAM backup, approximate 10 years life for data
retention.
Power input
Power supply voltage:
90 to 132 V AC (50/60 Hz)
[Including power supply voltage variation]
(Rating: 100 to 120 V AC)
180 to 264 V AC (50/60 Hz)
[Including power supply voltage variation]
(Rating: 200 to 240 V AC)
21.6 to 26.4 V DC
[Including power supply voltage variation]
(Rating: 24 V DC)
Specify when ordering
Power consumption:
100 to 120 V AC: 40 VA max.
200 to 240 V AC: 50 VA max.
24 V DC:
21 W max.
Surge current:
30 A or less
Power output (Function module power)
Output voltage/current:
5 V DC, 1.7 A max.
12 V DC, 1.0 A max.
Must be used within the maximum power consumption value.
Overcurrent protection:
Fold-back limiting method: 5 V