6. RKC COMMUNICATION
IMS01J02-E4
95
Continued from the previous page.
Name
Iden-
tifier
Digits
Attri-
bute
Struc-
ture
Data range
Factory
set
value
H-SIO-A input frequency
at full scale
[H-SIO-A]
JF
6 R/W
C 10 to 50000 Hz
130
H-SIO-A control range
[H-SIO-A]
SC
6 R/W
C 0.00 to 50.00 %
10.00
H-SIO-A output scale high
[H-SIO-A]
SU
6 R/W
C H-SIO-A output scale low to
10000 *
400
H-SIO-A output scale low
[H-SIO-A]
SD
6 R/W
C
9999 to
H-SIO-A output scale high *
0
H-SIO-A measuring
method
[H-SIO-A]
SP
1 R/W
C 0: Periodic computation method
1: Pulse count method
0
H-SIO-A divide ratio
[H-SIO-A]
SQ
6 R/W
C 1 to 1000
Effective only for periodic
computation method.
10
H-SIO-A gate time
[H-SIO-A]
RT
6 R/W
C 0.1 to 4.0 seconds
Effective only for pulse count
method.
1.0
H-SIO-A auto zero time
[H-SIO-A]
SA
6 R/W
C 1 to 100 seconds
5
H-SIO-A alarm hold
cancel time
[H-SIO-A]
SW
6 R/W
U 1 to 255 seconds
Setting will be invalid in
no alarm hold action.
60
H-SIO-A open/closed loop
control transfer
[H-SIO-A]
SM
1 R/W
C 0: Closed loop control
(PID control)
1: Open loop control
0
H-SIO-A correction trigger
[H-SIO-A]
SE
1 R/W
C 0: Normal
1: Correction executed
2: Correction canceled
Processing time of correction
execution or cancel is about one
second. Do not turn OFF the
power during the processing
time. In addition, maintain the
setting more than 0.5 second in
order to let it recognize
modification in setting
modification.
0
H-SIO-A correction actual
measured value
[H-SIO-A]
J2
6
R/W
C
Within display scale range *
0
* The position of the decimal point differs depending on Decimal point position (Identifier: XU) setting.