38
Pub. No. 1290 - January 2010
RITE-HITE
®
Dual-Dok
®
Combined Lift & Leveler System Owner’s Manual
FAULT CODES CONTINUED
Fault Shown On
Fault Code
Potential
Potential
Message Center
Numbers
Problems
Solutions
Scissors not
5
Lift down solenoid (A0201 is not
Verify that coil is plugged in and
dropping.
responding.
wires are not loose.
Loose connection with (X3F)
Verify all solenoid coil wire
terminal.
connections, voltages and
continuities.
Debris in not allowing cam
Remove all debris that is blocking
followers to roll.
cam follower movement.
Platform not
6
Platform separation limit switch
Verify that the platform separation
separating.
(E0204) is not responding when
limit switch assembly is not
platform separates.
damaged or set incorrectly.
Loose connection with +24VDC
Verify all limit switch wire
PLC input terminals.
connections, voltages and
continuities.
Platform separation limit switch
Replace platform separation limit
or cable is damaged.
switch assembly.
Gate motor
7
Gate motor is running to long or
Verify all limit switch wire
time out.
loose connections with +24VDC
connections, voltages and
PLC input terminals.
continuities.
Gate limit switches or cables
Verify that the gate limit switch
are damaged.
assemblies are not set incorrectly
or damaged. Replace gate limit
switch assemblies if damaged.
Gate travel is blocked.
Remove any debris blocking gate
travel.
Gate motor overload is tripped.
Reset motor overload located on
motor.
Velocity fuse
8
Too much weight on deck while
Remove weight on deck.
performing a Leveler Mode function.
Pressure line of ramp cylinder is
Check for broken hydraulic lines
broken or leaking.
or leaking valves.
Pressure on leveler relief valve
Increase pressure on the leveler
(LRV) is set too low.
relief valve (LRV on manifold).
(1/4 turn clockwise)
Platform separation limit switch
Verify that the platform separation
(E0204) is not responding when
limit switch assembly is not
platform separates.
damaged or set incorrectly.
Loose connection with +24VDC
Verify all limit switch wire
PLC input terminals.
connections, voltages and
continuities.
Platform separation limit switch
Replace platform separation limit
or cable is damaged.
switch assembly.
Содержание DUAL-DOK 2200
Страница 2: ...2 Pub No 1290 January 2010 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 61: ...Pub No 1290 January 2010 61 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 81: ...Pub No 1290 January 2010 81 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 82: ...82 Pub No 1290 January 2010 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 83: ...Pub No 1290 January 2010 83 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...