34
Pub. No. 1290 - January 2010
DUAL-DOK PLC INPUTS/OUTPUTS CHART
RITE-HITE
®
Dual-Dok
®
Combined Lift & Leveler System Owner’s Manual
SYSTEM DIAGNOSTICS CONTINUED
INPUTS
DESCRIPTION
STATE OF CONTACTS
AT STORED POSITION
PLC
DUAL-DOK 2200 PLC OUTPUTS (CONTROL BOX)
DUAL-DOK 2200 PLC INPUTS (CONTROL BOX)
TERM$
PLC
COM#
OUTPUTS
DESCRIPTION
PLC
TERM$
PLC
COM#
VOLTAGE
* IF OPTION IS NOT PROVIDED, TERMINAL BLOCK JUMPER IS INSTALLED TO HOLD INPUT CLOSED.
*
*
*
MANUAL/RESET PUSHBUTTON
NORMALLY OPEN
E6200
IN 0
E6201
E6202
E6203
E6204
E6205
E6206
OUTSIDE LIGHT SELECTOR SWITCH (ON RED)
E6207
DUAL-DOK 2000 CONTACTOR COIL ENERGIZED
E6500
OVERHEAD DOOR OPEN INTERLOCK
NORMALLY OPEN
E6501
NORMALLY CLOSED
E6502
GREEN LIGHT INTERLOCK WITH VEHICLE RESTRAINT
NORMALLY OPEN
RAISE LEVELER PUSHBUTTON
LIP OUT PUSHBUTTON
AUTO-LIP PUSHBUTTON
LIFT UP PUSHBUTTON
LIFT DOWN PUSHBUTTON
NORMALLY OPEN
NORMALLY OPEN
NORMALLY OPEN
NORMALLY OPEN
NORMALLY OPEN
NORMALLY OPEN
NORMALLY OPEN
MANUAL GATE CLOSED INTERLOCK
LIFT UP SOLENOID
24 VAC
A0200
A0201
A0202
A0203
A0204
A0205
-
-
24 VAC
24 VAC
24 VAC
24 VAC
24 VAC
-
-
PLATFORM/LIP SOLENOID
LIFT DOWN SOLENOID
AUTO-LIP SOLENOID
LIP OUT SOLENOID
PIN DISENGAGE SOLENOID
NOT USED
NOT USED
COM 0
COM 0
COM 0
COM 0
COM 1
COM 2
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN 10
COM 1
COM 1
COM 1
COM 2
COM 2
NORMALLY CLOSED HELD OPEN
NORMALLY OPEN HELD CLOSED
NORMALLY CLOSED HELD OPEN
NORMALLY OPEN HELD CLOSED
NORMALLY OPEN HELD CLOSED
PLATFORM SEPARATED FROM SCISSORS LIMIT SWITCH
SCISSORS SEPARATED IN LEVELER MODE LIMIT SWITCH
PLATFORM AT DOCK HEIGHT LIMIT SWITCH
-
NORMALLY CLOSED
-
NORMALLY OPEN HELD CLOSED
E0209
NORMALLY OPEN HELD CLOSED
E0208
E0207
E0206
E0205
E0204
E0203
E0202
E0201
E0200
NORMALLY CLOSED HELD OPEN
PIN DISENGAGE LIMIT SWITCH
PIN ENGAGE LIMIT SWITCH
PLATFORM BELOW DOCK HEIGHT LIMIT SWITCH
LIP EXTENDED LIMIT SWITCH
PLATFORM LEVEL LIMIT SWITCH
FLOAT SWITCH
NOT USED
LIP RETRACTED LIMIT SWITCH
-
NORMALLY OPEN
IN 11
COM 2
IN 12
COM 2
IN 13
COM 2
IN 14
COM 2
IN 15
COM 2
IN 16
COM 2
IN 17
COM 2
IN 18
COM 2
IN 19
COM 2
IN 20
COM 2
IN 21
COM 2
IN 22
COM 2
IN 23
COM 2
-
NOT USED
NOT USED
-
-
OUT 0
VAC/DC 0
-
-
24 VAC
24 VAC
24 VAC
24 VAC
24 VAC
ALARM HORN
OUTSIDE GREEN LIGHT
RED CAUTION BEACON
-
NOT USED
-
A6202
A6201
OSR
OSG
A6500
A6200
24 VAC
DUAL-DOK 2000 CONTACTOR COIL
OUTSIDE RED LIGHT
NOT USED
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
OUT 9
OUT 10
OUT 11
OUT 12
OUT 13
OUT 14
OUT 15
VAC/DC 1
VAC/DC 2
VAC/DC 2
VAC/DC 3
VAC/DC 4
VAC/DC 5
VAC/DC 3
VAC/DC 4
VAC/DC 5
VAC/DC 3
VAC/DC 4
VAC/DC 5
VAC/DC 3
VAC/DC 4
VAC/DC 5
LEVELER STORED INTERLOCK (TO VEHICLE RESTRAINT)
FIGURE 30 - PLC INPUTS/OUTPUTS CHART
Содержание DUAL-DOK 2200
Страница 2: ...2 Pub No 1290 January 2010 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 61: ...Pub No 1290 January 2010 61 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 81: ...Pub No 1290 January 2010 81 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 82: ...82 Pub No 1290 January 2010 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...
Страница 83: ...Pub No 1290 January 2010 83 RITE HITE Dual Dok Combined Lift Leveler System Owner s Manual NOTES...