8
2.1
Installation
2.1.1 Room/area
The room in which the machine is installed has to be well aerated and dry and the
temperature range is between 5 and 35°C.
Do not use the machine in humid (the humidity range is between 10 and 85% RH),
wet, dusty or explosive environment.
Provide good quality light and where is not subject to direct sunlight.
The machine must be placed on flat and smooth ground reasonably free from dust
and subject of no vibration, do not stand on paper waste.
Keep order around the machine.
Settle the machine to have minimum 1 meter free place round.
Operate this unit in the environment where there are no harmful chemicals and the
unit is not exposed to water.
Do not install this unit in a location where there is excessive humidity or where
contact with water is possible.
2.1.2 Fire & Explosion Hazard
Do not use flammable sprays inside or near the unit (e.g. when cleaning the unit).
2.1.3 Power Supply
The machine can be connected just to that electric network
which voltage, frequency and maximum power rating correspond to the values
displayed on the data table of the machine. To operate the machine, wire N is
necessary as well.
The machine has I. classing of protection against electric shock that is why it has to
be connected to grounded 400V 20A minimum nominal power rating socket being in
appropriate condition.
The electric socket-outlet must be easily accessible on behalf of the easier cutting off
the current, and above the floor level between 0,6 and 1,9m height.