The cross-section of the settled power cable has to be minimum 5 x 2,5 mm². To
protect the machine against too much power consumption, use single-phase C 25
circuit/contact breaker.
Carefully check the rotation of the motors.
At an occurred failure of the fuses change them just to the specified value, the
bridging of them or causing their short circuit is forbidden.
To attach other network appliances into the socket-outlet placed in the machine is
forbidden. The socket-outlet serves strictly to operate the external units of the
machine.