4.2.2. Scanner Switches
Scanner Switch 00
No
FUNCTION
COMMENTS
0
Not used
Do not change the settings.
1
Not used
Do not change the settings.
2
3
Maximum transmittable
document length
Bit 3 2 Setting
0 0 600 mm
0 1 1200 mm
1 0 14 m
1 1 Not used
If the user wants to send very long documents such as
well logs, select 14 m or a higher setting.
4
OR processing in immediate
tx
0: Disabled 1: Enabled
0: The machine scans once every 4 motor steps
(Standard), or once every 2 motor steps (Detail), and
transmits the line without OR processing. The motor
step is always 1/15.4 lines/mm.
1: The machine OR processes the scanned lines as
explained in section 2.1.3 - 6 “Sub-scan Resolution
Conversion”. Toner may be used up quicker if OR
processing is enabled.
5
to
7
Not used
Do not change the settings.
Scanner Switch 01 - Not used (do not change the factory settings).
Scanner Switch 02 - Not used (do not change the factory settings).
Scanner Switch 03 - Not used (do not change the factory settings).
Scanner Switch 04 - Not used (do not change the factory settings).
Scanner Switch 05 - Not used (do not change the factory settings).
Scanner Switch 06 - Not used (do not change the factory settings).
Scanner Switch 07 - Not used (do not change the factory settings).
Scanner Switch 08 - Not used (do not change the factory settings).
Scanner Switch 09 - Not used (do not change the factory settings).
Scanner Switch 0A - Not used (do not change the factory settings).
Scanner Switch 0B - Not used (do not change the factory settings).
Scanner Switch 0C - Not used (do not change the factory settings).
Scanner Switch 0D - Not used (do not change the factory settings).
Scanner Switch 0E - Not used (do not change the factory settings).
Scanner Switch 0F - Not used (do not change the factory settings).
SERVICE TABLES AND PROCEDURES
May 22nd, 1995
BIT SWITCHES